⚡ Cathodic Protection Interference and Its Mitigation
📘 Course Description This 5-day intensive course equips corrosion, CP, and pipeline professionals with the skills to identify, measure, analyze, and mitigate electrical interference affecting cathodic protection systems on pipelines, tanks, and marine structures. Participants will gain hands-on experience in …
Overview
📘 Course Description
This 5-day intensive course equips corrosion, CP, and pipeline professionals with the skills to identify, measure, analyze, and mitigate electrical interference affecting cathodic protection systems on pipelines, tanks, and marine structures. Participants will gain hands-on experience in assessing both AC and DC interference, designing mitigation measures, and ensuring compliance with international standards.
🎯 Learning Objectives
✅ Understand AC/DC interference mechanisms on CP systems
✅ Identify interference sources such as railways, HV lines, and foreign pipelines
✅ Conduct field measurements and analyze interference data
✅ Design and implement effective mitigation systems
✅ Apply international standards (NACE SP0169, EN 50162)
👥 Who Should Attend
-
Corrosion & CP engineers
-
Pipeline integrity engineers
-
CP technicians and inspectors
-
Asset integrity managers
-
EPC professionals involved in pipeline design & maintenance
🗂️ Training Format
✅ Instructor-led lectures
✅ Group case studies
✅ Hands-on calculations
✅ Practical field measurement techniques
✅ Interactive discussions
📅 Day-by-Day Agenda with Time Breaks
📅 Day 1: Introduction to CP Interference
Time | Topic |
---|---|
08:30 – 09:00 | Course Objectives & Introduction |
09:00 – 10:30 | CP Fundamentals: Galvanic & Impressed Systems |
10:30 – 10:45 | ☕ Coffee Break |
10:45 – 12:15 | Basic Electrochemistry & Polarization |
12:15 – 13:15 | 🍽 Lunch |
13:15 – 14:45 | Mechanisms of CP Interference (AC/DC, telluric, lightning) |
14:45 – 15:00 | ☕ Coffee Break |
15:00 – 16:30 | Standards & Guidelines (NACE SP0169, EN 50162) |
📅 Day 2: Sources & Effects of Interference
Time | Topic |
---|---|
08:30 – 10:00 | AC Interference: HV Power Lines, Transformer Stations |
10:00 – 10:15 | ☕ Coffee Break |
10:15 – 12:15 | DC Stray Currents: Railways, Industrial Installations |
12:15 – 13:15 | 🍽 Lunch |
13:15 – 14:45 | Telluric Currents & Lightning Effects |
14:45 – 15:00 | ☕ Coffee Break |
15:00 – 16:30 | Case Studies: Pipeline Failures Due to Interference |
📅 Day 3: Measurement & Field Techniques
Time | Topic |
---|---|
08:30 – 10:00 | Interference Voltage & Current Measurement Methods |
10:00 – 10:15 | ☕ Coffee Break |
10:15 – 12:15 | On-site Measurement Equipment & Best Practices |
12:15 – 13:15 | 🍽 Lunch |
13:15 – 14:45 | Analyzing Data for Interference Assessment |
14:45 – 15:00 | ☕ Coffee Break |
15:00 – 16:30 | Identifying High-Risk Locations |
📅 Day 4: Mitigation Design & Implementation
Time | Topic |
---|---|
08:30 – 10:00 | Mitigation Strategies Overview: Bonds, Decouplers, Gradient Control Mats |
10:00 – 10:15 | ☕ Coffee Break |
10:15 – 12:15 | Designing Mitigation Systems: Case Calculations |
12:15 – 13:15 | 🍽 Lunch |
13:15 – 14:45 | Installation & Commissioning of Mitigation Devices |
14:45 – 15:00 | ☕ Coffee Break |
15:00 – 16:30 | Ensuring Safety & Compliance in Mitigation Works |
📅 Day 5: Post-Mitigation Monitoring & Case Studies
Time | Topic |
---|---|
08:30 – 10:00 | Post-Mitigation Monitoring Programs |
10:00 – 10:15 | ☕ Coffee Break |
10:15 – 12:15 | Long-Term Maintenance of Mitigation Systems |
12:15 – 13:15 | 🍽 Lunch |
13:15 – 14:45 | Case Studies: Successful and Failed Mitigation Projects |
14:45 – 15:00 | ☕ Coffee Break |
15:00 – 16:30 | Group Exercise: Developing a Complete Interference Mitigation Plan & Course Wrap-Up |
📦 Materials Provided
✅ Course manual & handouts
✅ Field measurement templates
✅ Calculation spreadsheets
✅ NACE & EN standards references
✅ Access to instructor for post-course support
Target audiences
- Reservoir Engineers, Geologists